12 12 12 251 Components and spare parts from page 474 to 482 Valid until December 31, 2019 Hand tools VDE Tools for Electricians VDE tools For safe application up to 1000 volts Special HAZET VDE protective insulation What are VDE tools? • VDE tools have a special protective insulation and must be tested according to IEC 60900. • The standard also prescribes the marking with the manufacturer name, model and type designation and year of manufacture. VDE tools are identified by the “Double triangle” logo and the 1000 V specification and the VDE logo. • All requirements stipulated in the DIN ISO for the torque, forces and hardness, for example, must be complied with. • HAZET VDE tools normally have a two- tone multilayer safety insulation, i.e. a red layer on the outside and a yellow layer on the inside. This design supports building regulation BGV A3 (VBG-4) • The insulation must not exhibit any visual damage. If the inner yellow insulation layer is visible anywhere, the tool must be disposed of immediately since there is a risk of electric shock. It is no longer possible and extremely dangerous to work with the power connected. • VDE tools with sprayed on insulation only have a single red layer. For safety reasons, the user should therefore check that the insulation is intact before starting work with the power connected to guarantee his safety.